News

Radiator coolant of a diesel generator: Rust preventive & Antifreeze Coolant

Published on 27 August, 2021

Radiator coolant of a diesel generator: Rust preventive & Antifreeze Coolant

Radiator coolant of a diesel generator: Rust preventive & Antifreeze Coolant

When the generator set runs, the diesel engine pumps coolant to the radiator to bring away heat generated by the engine. There are two main types of coolants, where the coolant fluids are composed of purified water and rust preventive or antifreeze:

  1. Rust preventive: an anti-rust liquid to prevent corrosion in most conditions.
  2. Antifreeze: in addition to the anti-rust property, an antifreeze is for operation under cold weather conditions. It prevents water from freezing which may damage the internal components.

For Cummins diesel generators, Fleetguard coolants are a convenient choice to ensure the coolant circulates effectively. There is no need to add water when using Fleetguard coolants. There are other alternatives, but you may have to mix the liquids in different ratios according to specific temperature requirements.

Why do we use 2 pack paint for our containerised sets?

Published on 23 July, 2021

Why do we use 2 pack paint for our containerised sets?

2 Pack Paint, also known as 2 Pack or 2-pac, is an acrylic enamel paint in the spray painting industry. 2 Pack Paint produces high-gloss, smooth, durable, and luxurious finishes based on polyurethane for exposed surfaces. It does not peel and maintain vibrant colour without becoming dull. Due to its weatherproof nature, 2 Pack Paint is more resistant to damage and is commonly used in the automotive industry.

Due to its superior quality to alternative painting techniques, we utilise 2 pack paint in containerised and canopy sets of our diesel generators. You may choose from a huge range of RAL colours for the colour of your power box. The RAL Classic colours have a 4-digit structure, and the first digit is a system code number (1: yellow, 2: orange, 3: red, 4: violet, 5: blue, 6: green, 7: grey, 8: brown, and 9: white and black). The remaining digits are sequentially arranged.

Emergency stops in diesel generator sets

Published on June 25, 2021

emergency stops in diesel gensets

Mechanical & electronic emergency stops in containerised diesel generator sets

Normally, a cool-down process is required for a shutdown of the diesel generator sets. In case of an emergency – such as fire, gas leak etc – the emergency stops are useful to bypass time delay to cut off the supply of fuel directly. So that an absence of fuel prevents the diesel generator from operating. There are mainly 2 types of emergency stops: Electronic & Mechanical.

  • Electronic: when pressing the electronic emergency stop button, the control panel will send signals to halt the fuel pump operation safely.
  • Mechanical: when pulling the handle of the mechanical emergency stop to full extend, a conduit attached (with a wire within) will close the opening mounted on the fuel pump.

Our containerised diesel generator sets are equipped with electronic emergency stops. For local projects in Hong Kong, an extra mechanical emergency stop is often installed to provide additional protection to meet fire safety requirements. If you need to perform an emergency shutdown operation, attempt the electronic emergency stop before using a mechanical emergency stop. After using the emergency stops, the stop devices have to be restored before restarting the generator set.

Design of Cable Outlet in Diesel Generator Sets

Published on April 15, 2021

Design of Cable Outlet in Diesel Gensets

Different users have their preferences on power distribution in a generator set, and this area can be customised. As requested, this time we added a cable outlet cover for extra protection and opening vertically. The gas spring within holds the cover firmly once opened. This protects users’ fingers from hurting while connecting the cables. Additionally, after opening up the cover, it is slightly downward instead of completely horizontal. This provides a water repellent function along with the rain guard at the top.